GridBit LV switchgear monitoring

GridBit brings the low-voltage board of a secondary substation online. A network analyser measures current, voltage, power and power quality on every phase, and a voltage detector watches the outgoing feeders, fuses and protections.

  • Modbus modules and third-party sensors
voltage inputs on one SMU-3 detector
8
active power accuracy of MCU-4
±1 %
harmonic orders the platform shows per phase
3 to 13
Modbus devices one gateway can read
127

The problem

The first report often comes from a customer

Below the secondary substation the operator often learns about a fault from the customers. Without data from the low-voltage board, a DSO faces:

  1. 01More frequent and longer interruptions, worse SAIDI and SAIFI

How it works

From the DIN rail to the platform

The modules mount on the DIN rail of the board and share one Modbus RTU line with the gateway.

01MCU

Every phase of the busbar

The MCU-4 network analyser measures voltage, current, active, reactive and apparent power, cos φ and energy on each phase. Its active power accuracy is ±1 %.

Open the module

02SMU

A voltage check on every feeder

The SMU-3 detector reads AC voltage on eight inputs, isolated by 5000 V from its supply and the bus. A feeder whose fuse has blown or whose protection has tripped shows up as an input without voltage. The relay unit (RLU) switches lines on a schedule or on command.

Open the module

03GWU

One gateway for the board

The GWU-5 gateway reads up to 127 Modbus devices on one bus and sends their data with MQTT over 4G LTE, with 2G as fallback, or over Ethernet.

Open the module

04WDT

Keeps the electronics running

Surges and harmonics on the supply can make electronics hang. The WDT-1 watchdog relay follows the Modbus communication and, when it stops, operates its relay for a set time to restart the devices.

Open the module

05Platform

The board in a browser

The platform shows the busbar and every outgoing circuit, and the power quality of the past week, phase by phase.

The platform

Every circuit of the board on one screen

The busbar and every circuitPower quality over a week

The busbar and every circuit

Current and voltage per phase with the minimum, average and maximum for the period, then the same for each outgoing circuit.

Power quality over a week

Voltage deviation, rapid voltage changes, asymmetry and harmonics from the 3rd to the 13th with the total distortion, per phase.

Keep scrolling

Screens from the interface design, with sample data.

The platform

Every circuit of the board on one screen

  1. The busbar and every circuit

    The busbar and every circuit

    Current and voltage per phase with the minimum, average and maximum for the period, then the same for each outgoing circuit.

  2. Power quality over a week

    Power quality over a week

    Voltage deviation, rapid voltage changes, asymmetry and harmonics from the 3rd to the 13th with the total distortion, per phase.

Screens from the interface design, with sample data.

Functions

Set to your processes and systems

01

Automation

Processes, tasks, analyses and reports set to the needs of the client.

02

Integration

With systems of other vendors through standard protocols.

03

System configuration

Devices, users and thresholds managed from the interface.

Benefits

Faster response, safer work

Efficient operation

Faults and disruptions are detected at once, response is quick and downtime is short.

Safety

Hazards are identified early, so crews act in time and the risk of accidents drops.

In the field

The same modules run in street lighting cabinets

MCU-4 and SMU-3 already work in the field: they are part of GridBit street lighting management, the system that switches and measures street lighting cabinets across Bulgaria.

street lighting cabinets
4 500+
municipalities
70+

Questions

Short answers

Another question? Ask an engineer

What does the system measure at the low-voltage board?

Current, voltage, power and power quality on every phase, and the state of the outgoing feeders, fuses and protections. On the DIN rail, the MCU-4 network analyser measures each phase and the SMU-3 voltage detector reads eight inputs.

Which power quality values does the platform show?

Voltage deviation, rapid voltage changes, asymmetry and harmonics from the 3rd to the 13th with the total distortion, per phase. The busbar view adds current and voltage per phase with the minimum, average and maximum for the period.

Does it work with systems and sensors from other vendors?

Yes. The platform integrates with systems of other vendors through standard protocols, and third-party Modbus sensors connect to the same line as the GridBit modules.

Are these the same modules as in street lighting cabinets?

Yes. MCU-4 and SMU-3 are also part of GridBit street lighting management, which runs in more than 4 500 street lighting cabinets in more than 70 municipalities in Bulgaria.

Ask for a proposal for your LV boards

Tell us how many boards you want to monitor and which values matter to you. We propose the modules and the gateway and send a quote.